Vortex flowmeter LUCB series
LUCB type plug-in vortex flow sensor, can be widely used in various industries large diameter gas, liquid, steam flow measurement, can also be measured containing tiny particles, impurities of turbid liquid, and can be used as a flow transmitter for automatic control system.
Key words:
Classification:
Telephone:
E-mail:
Vortex flowmeter LUCB series
Product overview
LUCB type plug-in vortex flow sensor, can be widely used in various industries large diameter gas, liquid, steam flow measurement, can also be measured containing tiny particles, impurities of turbid liquid, and can be used as a flow transmitter for automatic control system.
Working principle
According to the International Organization for Standardization IS07145 (velocity measurement method for measuring fluid flow in a closed pipe with an annular cross-section at a point in the cross-section), a vortex velocity probe embedded in a piezoelectric crystal is inserted into a large-diameter industrial pipe to convert the Karman vortex frequency into a current or voltage pulse signal proportional to the flow or a 4~20mADC current signal.
Product Features
1. The use of anti-interference circuit and anti-vibration sensor head, so that the instrument has a certain anti-environmental vibration performance.
2. The pressure loss is small, the measuring range is wide, and the range is 1:10.
3. No moving parts, long-term stability, simple structure and easy installation and maintenance.
4. The regular temperature resistance of the measurable medium is 250 ℃, and the high temperature type can reach 350 ℃.
Technical parameters
Nominal diameter (mm) |
250,300,350,400,450,500,600,700,800,900,1000 |
Instrument material |
1Cr18Ni9Ti |
Nominal pressure (MPa) |
PN1.6MPa,PN2.5MPa |
Temperature of measured medium (℃) |
-40~250 ℃ |
Environmental conditions |
Temperature -10~+55 ℃, relative humidity 5% ~ 90%, atmospheric pressure 86 ~ 106kpa |
Accuracy Class |
Measuring liquid: ± 2.5% of the indicated value |
Span ratio |
1:10,1:15 |
coefficient of resistance loss |
Cd<2.6 |
Output signal |
Three-wire system: pulse frequency signal 0.1~3000Hz low level ≤ 1V high level ≥ 6V Two-wire system: two-wire system 4~20mADC current signal |
Power supply |
Pulse without display: 12/24VDC Field display type: the instrument comes with 3.6V lithium battery, 24VDC (optional) optional) |
signal transmission line |
STVPV3 × 0.3 (three-wire system),2 × 0.3 (two-wire system) |
Transmission distance |
≤ 500m |
Signal line interface |
Internal thread M20 × 1.5 |
Explosion-proof grade |
ExdlIBT6 |
Protection level |
IP65 |
Allowable vibration acceleration |
1.0g |
Selection
Product Model and Marking |
Description |
|||||||
Model |
LUCB |
|
|
|
|
|
|
|
Measured medium |
Gas |
1 |
|
|||||
Liquid |
2 |
|
||||||
Steam |
3 |
|
||||||
Caliber |
025 |
250mm |
||||||
030 |
300mm |
|||||||
035 |
350mm |
|||||||
040 |
400mm |
|||||||
045 |
450mm |
|||||||
050 |
500mm |
|||||||
060 |
600mm |
|||||||
070 |
700mm |
|||||||
080 |
800mm |
|||||||
090 |
900mm |
|||||||
100 |
1000mm |
|||||||
110 |
1100mm |
|||||||
120 |
1200mm |
|||||||
130 |
1300mm |
|||||||
140 |
1400mm |
|||||||
150 |
1500mm |
|||||||
|
N |
12/24VDC power supply, no display, pulse output |
||||||
B |
Battery Powered, Field Display, Pulse Output |
|||||||
C |
12/24VDC power supply, field display, 4-20mA/pulse output |
|||||||
E |
Battery powered, field display, 485 communication output |
|||||||
H |
12/24VDC power supply, field display, HART output |
|||||||
|
W |
|
temperature compensation |
|||||
Y |
Pressure compensation |
|||||||
G |
High temperature type |
|||||||
F |
split type |
|||||||
|
E |
Explosion proof, ExdlIBT6 |
||||||
N |
No explosion-proof |
Applicable flow ranges for general liquids and gases
Nominal diameter DN(mm) |
Flow range (m³/h) |
Nominal diameter DN (Mm) |
Flow range (m³/h) |
||
Liquid |
Gas |
Liquid |
Gas |
||
250 |
80-1150 |
1060-10600 |
800 |
720-10800 |
10850-108500 |
300 |
130-1400 |
1540-15400 |
900 |
970-12000 |
13000-130000 |
350 |
140-2100 |
2100-21000 |
1000 |
1130-16900 |
17000-170000 |
400 |
180-2700 |
2700-27000 |
1100 |
1450-18000 |
19000-190000 |
450 |
240-3400 |
3400-34000 |
1200 |
1630-24400 |
24400-244000 |
500 |
280-4200 |
4240-42400 |
1300 |
2020-25300 |
27000-270000 |
600 |
410-6100 |
6100-61000 |
1400 |
2350-29500 |
31000-310000 |
700 |
580-7300 |
7800-78000 |
1500 |
2550-38000 |
38200-382000 |
Factory display

Plant display 7

Plant display 8

Plant display 6

Plant display 5

Plant Display 4

Plant Display 9

Plant Exhibition 3

Plant display 2

Factory display
Honor Show

Exhibition style

Previous Page
Next Page
Previous Page
Electromagnetic flowmeter
Next Page
Related Products
Product Consulting
We will contact you within one working day. Please pay attention to your email.